Inductance Calculator
Compute a solenoid's inductance from turns, area and length, or the voltage induced by a current change through a known inductance.
Two inductance facts
In solenoid mode, enter the turn count, the core cross-section in cm² and the coil length in cm. The page applies L = μ₀·N²·A / l with μ₀ = 4π×10⁻⁷ H/m, converting the area and length to square metres and metres first, and prints the result in henries and microhenries. In induced-voltage mode it applies Faraday's law in the form V = L·ΔI / Δt from an inductance in henries and a current change over a time.
The solenoid formula assumes a long, air-cored coil with the field uniform across its cross-section and no fringing at the ends. A short coil reads lower than this predicts, a ferromagnetic core multiplies the answer by a permeability the page does not ask for, and the induced-voltage mode assumes L stays constant while the current changes. A zero length or zero time is refused rather than divided by.
All of the arithmetic runs in this tab. Nothing is uploaded, no coil is stored, and the same dimensions print the same inductance after a reload.
Two inductance facts in one page: the solenoid L = μ₀·N²·A / l with μ₀ = 4π×10⁻⁷ H/m, and the induced voltage V = L·ΔI / Δt. A hundred turns over 1 cm² and 10 cm gives 1.2566×10⁻⁵ H.
The solenoid form assumes a long air-cored coil with a uniform field, so a short coil reads lower and a ferromagnetic core is not modelled. A zero length or zero time is refused.
How to use it
Pick what to compute. In solenoid mode, enter the turns, the core area in cm² and the coil length in cm; in induced-voltage mode, enter the inductance in henries, the current change and the time it takes. Press Run for the answer and the formula with the values substituted.
The arithmetic
The solenoid formula converts cm² to m² and cm to m before multiplying, squares the turn count and divides by the length, then prints both henries and microhenries. The induced-voltage mode multiplies the inductance by the current change and divides by the time, which is Faraday’s law for a constant L.
Where it stops
Fringing at the ends of a short coil, a magnetic core with a permeability above μ₀, and a changing inductance while the current ramps are all outside the model. The page refuses a zero length or zero time rather than dividing by it, and it does not compute the energy stored or the resonant frequency.
What to Expect
Best for
- Sizing an air-cored coil from a datasheet.
- Checking the voltage a current change induces.
What this tool keeps
- The dimensions and currents are computed in the browser and never posted, so the page works offline and retains nothing.
Sample input
Solenoid: 100 turns, 1 cm², 10 cm
Sample output
L = 1.2566e-5 H L = μ₀·N²·A / l with μ₀ = 4π×10⁻⁷ H/m 100 turns, 1 cm², 10 cm — 12.566371 µH
Frequently asked questions
How do I use it?
Choose solenoid or induced voltage, fill in the fields that mode needs, then press Run. Both the answer and the formula with your numbers are printed.
Is anything uploaded?
No. The arithmetic runs in this tab with JavaScript: no request is made, no account is needed, nothing is stored, and the page keeps working offline once loaded.
What are its limits?
The solenoid must be long and air-cored for the formula to hold, and the voltage mode must have a non-zero time; a ferromagnetic core or a short coil needs a different model.
Build custom tools for your store
Join the SDK program to create useful ecommerce utilities for your store.