Radiation Converter

Convert between sievert, gray and roentgen units, with the weighting assumption stated rather than hidden.

Privacy First
0 Runs
Updated 2026-11-06
No upload
No signup
Runs in this tab

Two dose scales and an exposure unit

The page converts between Sv, mSv, µSv, Gy, mGy, µGy, R and mR. It reduces the input to a base value and prints the target unit with the substitution shown. Roentgen is an exposure unit, taken here as 1 R = 8.77×10⁻³ Gy in air; sievert and gray are converted 1:1, which holds only for photons, where the radiation weighting factor is 1.

When the conversion crosses from exposure or absorbed dose into dose equivalent, the page states that the weighting factor was assumed to be 1 and that a neutron or alpha dose would need its own factor, which this page does not apply. It is unit arithmetic, not a dose assessment, a limit or a safety clearance, and it says so on every answer.

Nothing is uploaded and no value is stored. The same number and the same two units always print the same conversion.

Convert between sievert, gray and roentgen units, reducing the input to a base value and printing the target with the substitution shown.

It is unit arithmetic with the weighting assumption stated — not a dose assessment, a limit or a safety clearance — and nothing leaves the tab.

How to use Radiation Converter

Pick the From unit and the To unit from the eight offered — Sv, mSv, µSv, Gy, mGy, µGy, R and mR — and type the Value.

Press Run and read the converted dose, with the substitution printed beside it.

Check the assumption stated beside the converted dose: Sv and Gy are treated as the same number here, which a photon dose allows and a neutron dose does not.

Exposure, absorbed dose, dose equivalent

The three scales answer different questions. Roentgen measures ionisation in air, gray measures energy deposited per kilogram of material, and sievert measures biological effect, which is gray multiplied by a radiation weighting factor. This page converts R to a gray-equivalent in air and treats Sv and Gy as the same number, which is what a photon dose allows.

Keeping the distinction visible is the point of the page: a figure in mGy and a figure in mSv look interchangeable and are not, and the answer states which assumption was made rather than leaving it implicit.

What to Expect

Best for

  • Converting a figure quoted in roentgen into gray or sievert.
  • Scaling between mGy and µGy without losing a factor of a thousand.

What this tool keeps

  • The conversion is arithmetic in this tab and the value is never posted, so nothing is stored and the page works offline.

Sample input

1 R to mGy

Sample output

1 R = 8.77 mGy Base value 0.00877 Gy-equivalent in air; 1 R is taken as 8.77×10⁻³ Gy in air. Unit arithmetic only. It is not a dose assessment, a limit or a safety clearance.

Frequently asked questions

Which units are supported?

Sv, mSv and µSv for dose equivalent; Gy, mGy and µGy for absorbed dose; and R and mR for exposure, taken here as 1 R = 8.77×10⁻³ Gy in air.

Is one sievert one gray?

Numerically here, yes, and that holds only for photons, where the radiation weighting factor is 1. A neutron or an alpha dose needs its own factor, which this page does not apply — the answer says so when the conversion crosses families.

Is this a dose assessment?

No. It is unit arithmetic. It is not a dose assessment, a limit or a safety clearance, and no value is uploaded or stored.