Electrochemical Cell Potential Calculator
Find the standard cell potential from the two electrode potentials with E°cell = E°cathode - E°anode.
Standard cell potential from two electrodes
Both potentials are entered as standard reduction potentials in volts, the way they are tabulated. The page subtracts the anode value from the cathode value: copper at +0.34 V against zinc at -0.76 V gives +1.10 V. The second line repeats the two values and says whether the cell as written is spontaneous.
The two values are not checked against a table of standard potentials, because the page carries no such table. That means a sign typed the wrong way changes the answer and the page cannot catch it. Equal potentials are allowed and print zero with a note that there is no net cell reaction.
The subtraction is the whole computation. Reloading the page reproduces the same potential, and neither electrode value is stored or sent anywhere.
The page computes the standard cell potential as E°cell = E°cathode − E°anode, both entered as standard reduction potentials in volts the way they are tabulated. Copper at +0.34 V against zinc at −0.76 V gives +1.10 V.
The sign of the result is the answer: positive means the cell as written is spontaneous, negative means it runs the other way. The page carries no table of standard potentials, so a value typed with the wrong sign changes the result and cannot be caught here.
How to use it
Enter both electrodes as reduction potentials in volts, with their signs, and press Run. The second line repeats the two values and states whether the cell as written is spontaneous.
- Enter the cathode's standard reduction potential in V.
- Enter the anode's standard reduction potential in V, keeping its sign.
- Read the difference and the spontaneity note beneath it.
The arithmetic, and where it stops
One subtraction produces the answer, so the page is exact for the numbers typed: 0.34 − (−0.76) = 1.10 V. Standard potentials are quoted against the same hydrogen reference, which is what makes the subtraction legitimate; mixing a value from another reference scale breaks that assumption silently, because the page cannot see where a number came from.
Equal potentials are allowed and print zero with a note that there is no net cell reaction, and a non-numeric field is refused with the field named. Nothing is clamped: a negative standard potential is meaningful and is printed as typed.
What to Expect
Best for
- Subtracting two tabulated standard potentials for one cell.
What this tool keeps
- The subtraction is done in this tab, so no electrode data is uploaded, stored or remembered. The same figures give the same result after a reload.
Sample input
0.34, -0.76
Sample output
E°cell = 1.10 V (spontaneous as written)
Frequently asked questions
How do I use the Electrochemical Cell Potential Calculator?
Enter both electrodes as reduction potentials in volts, with their signs, and press Run. The second line repeats the two values and states whether the cell as written is spontaneous.
Does anything leave my browser?
No. The subtraction is done in this tab, so no electrode data is uploaded, stored or remembered. Reloading the page discards every value you entered.
Which inputs does it refuse?
Equal potentials are allowed and print zero with a note that there is no net cell reaction, and a non-numeric field is refused with the field named. Nothing is clamped: a negative standard potential is meaningful and is printed as typed.
Build custom tools for your store