Wire Gauge Calculator
Look up AWG wire diameter, area, and resistance.
Look up AWG wire diameter, area, and resistance. Enter your numbers and get an instant result.
Choose an American Wire Gauge size and this page reports the conductor diameter in millimetres and inches, the cross-sectional area in square millimetres, a copper resistance per kilometre and an ampacity figure from a fixed guide table.
Diameter follows the standard AWG formula, which halves the area every three gauge steps. Resistance uses the resistivity of copper, so it is a property of the metal at a nominal temperature rather than of any particular cable.
The ampacity column is a lookup, not a calculation: it holds values for eleven sizes and prints `Signal / Low Voltage Only` for the rest, including every size below 14 AWG.
The formula and the table
Diameter is 0.127 times 92 raised to (36 minus the gauge) over 39, in millimetres. The 0000, 000 and 00 sizes are mapped to -3, -2 and -1 before the formula runs, which is why the large sizes are ordered correctly.
Area is pi times half the diameter squared. Resistance is 17.2 divided by the area in square millimetres, giving ohms per kilometre for copper.
The ampacity table covers 14, 12, 10, 8, 6, 4, 2, 1/0, 2/0, 3/0 and 4/0. A size outside that set has no entry and says so rather than interpolating.
- Diameter: 0.127 * 92 ^ ((36 - gauge) / 39) mm
- Area: pi * (diameter / 2) squared
- Resistance: 17.2 / area, ohms per kilometre
Why the ampacity figure is only a guide
Real current-carrying capacity depends on insulation temperature rating, ambient temperature, bundling, conduit fill and whether the run is in free air. The table here is one number per size and encodes none of those.
The ratings also differ between codes and between countries. Treat the column as a starting comparison and take the installed value from the code your installation is inspected against.
How to use the gauge selector
Choose an AWG size in the Gauge Selector, or start from a Common Household Preset. Diameter follows the standard formula that halves the area every three gauge steps.
Read diameter in millimetres and inches, cross area, copper resistance per kilometre and the ampacity lookup. Sizes without a table value, everything below 14 AWG, read `Signal / Low Voltage Only`.
What to Expect
Best for
- Looking up the diameter and area of a gauge size
- Comparing copper resistance across two sizes
- Checking a rough current guide for common household sizes
Not ideal for
- Specifying a circuit for an inspection, which needs the applicable code
- Aluminium conductors, whose resistance and ampacity differ
- A gauge below 14 AWG, which has no ampacity entry here
What this tool keeps
- Four decimal places on diameter and area
- Three decimal places on resistance per kilometre
- A stated fallback for sizes the ampacity table does not cover
What may need cleanup
- The ampacity number, which ignores insulation, ambient temperature and bundling
- The resistance figure, which is a nominal copper value at one temperature
- Sizes below 14 AWG, which report no current rating at all
Common errors
- Treating the ampacity guide as a code-compliant rating
- Reading the resistance as a measurement of a particular cable
- Expecting an ampacity for 18 or 20 AWG and reading the fallback as missing data
Example use cases
- Comparing 12 and 14 AWG for a 20 amp circuit
- Calculating voltage drop over a long run
- Checking the physical size of a conductor before buying
Sample input
Select 14 AWG, or press the 14 AWG (15A) preset.
Sample output
1.6277 mm across, 2.0809 square millimetres, about 8.266 ohms per kilometre and 15 Amps.
Who this is for
- Electricians checking a size against a rule of thumb
- Electronics hobbyists comparing conductor sizes
- Students learning the AWG scaling relation
Frequently asked questions
What does the wire gauge page report?
For an American Wire Gauge size: diameter in millimetres and inches, cross-sectional area, a nominal copper resistance per kilometre and an ampacity figure from a fixed table.
Can I use the ampacity figure for an inspection?
No. It is a guide value that ignores insulation, ambient temperature and bundling, so the applicable code governs a real circuit.
Why is there no current rating below 14 AWG?
The ampacity table has no entry below 14 AWG, and the page states that fallback rather than inventing a number.